Tuloc

Precise marking of breast lesions

Anchoring

Secure anchoring in tissue through the double hook with sharp tips

Brusttumor Lokalisation, Clipmarkierung, biopsy site marker

Repositioning

Wire can be pulled back into the cannula and released again

Single-handed operation

Tuloc Premium for ultrasound-guided operation using one hand

Tuloc

Monofilament localization wire

Tuloc is used for marking non-palpable, suspicious breast lesions prior to surgery. The monofilament, rigid marking wire facilitates the intraoperative localization of findings for surgeons. 20-gauge thin, sharp puncture cannulas ensure minimally invasive treatment.

  • Monofilament marking wire made from Nitinol for intraoperative localization of findings
  • 2 cm long reinforcement tube made from stainless steel before the tip for intraoperative depth orientation
  • Distal double hook expands upon deployment and anchors firmly in the tissue
  • Sharp tips of the hooks assist penetration of tumor tissue
  • Position can be corrected by pulling wire back into cannula
  • Tuloc deployment systems are designed for a range of applications

The localization wire is pushed out of the cannula. The double hook expands upon deployment and anchors firmly in the tissue.

Tuloc localization kits

The choice is yours

Drahtmarkierung

Tuloc

  • With 20-Gauge puncture cannula
  • Puncture cannula suitable for stereotactic surgery
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings
  • Sharp and echogenic cannula tip
Drahtmarkierung

Tuloc Premium

  • With 20-Gauge puncture cannula and ergonomic handle
  • Handle for ultrasound-guided operation using one hand
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings
  • Sharp and echogenic cannula tip with ultrasonically visible marking
Drahtmarkierung

MR Tuloc

  • With MRI compatible 20-Gauge puncture cannula for MRI-guided wire marking up to 3 Tesla
  • Reinforcement tube and cannula made from nickel-cobalt
  • Position can be corrected by pulling wire back into cannula
  • Cannula with depth markings

Order information

Drahtmarkierung
Product code Gauge Ø Cannula length
Tuloc 271660 20 0.95 mm 50 mm
271661 20 0.95 mm 90 mm
271663 20 0.95 mm 120 mm
Tuloc Premium 271880 20 0.95 mm 50 mm
271881 20 0.95 mm 90 mm
271883 20 0.95 mm 120 mm
MR Tuloc 601649 20 0.95 mm 90 mm
601651 20 0.95 mm 120 mm

Packaging unit: 10 items, shelf life from production date: 5 years

Order information

Drahtmarkierung

Product code Tuloc
271660 / 20 G / 50 mm
271661 / 20 G / 90 mm
271663 / 20 G / 120 mm

Product code Tuloc Premium
271880 / 20 G / 50 mm
271881 / 20 G / 90 mm
271883 / 20 G / 120 mm

Product code MR Tuloc
601649 / 20 G / 90 mm
601651 / 20 G / 120 mm

Packaging unit: 10 items, shelf life from production date: 5 years